Skip to the content

Heating and Cooling Repairs

No heat, no cooling, weak airflow or a new noise: how the common faults show themselves, and what to check before you call.

A heating or cooling system rarely fails without a warning. The blower sounds different for a week, the air from the registers is a little less cold, the furnace starts and stops more often than it used to. By the time the house is uncomfortable, the cause has usually been building for a while, and it is often a single part: a capacitor that has weakened, a flame sensor coated with residue, a clogged condensate line, a refrigerant leak at a joint.

A repair visit starts with measurement rather than guesswork. The temperature difference across the coil, the airflow at the registers, the system pressures and the electrical readings on motors and capacitors each point toward or away from a cause. The fault is traced to its source, explained, and only then fixed, so a part isn’t swapped on a hunch.

Symptoms and Their Usual Causes

SymptomCommon causesSystem affected
No heatCommon causesThermostat setting or wiring, failed igniter or flame sensor, tripped high-limit switch, gas supply offSystem affectedFurnace, heat pump
No coolingCommon causesFailed capacitor or contactor, tripped breaker, low refrigerant, outdoor fan motor stoppedSystem affectedCentral AC, heat pump, mini-split
Weak airflowCommon causesClogged filter, dirty blower wheel, crushed or disconnected duct, restricted returnSystem affectedAll ducted systems
Short cyclingCommon causesOversized equipment, overheating from poor airflow, faulty flame sensor, thermostat placementSystem affectedFurnace, AC, heat pump
Strange noisesCommon causesLoose blower wheel, worn motor bearings, failing capacitor hum, debris in the outdoor fanSystem affectedFurnace, AC, heat pump
Frozen coilCommon causesLow airflow across the coil, low refrigerant charge, a blower that has stoppedSystem affectedCentral AC, heat pump
Water leaksCommon causesClogged condensate drain, cracked drain pan, failed condensate pump, ice melting off the coilSystem affectedAC, high-efficiency furnace
Thermostat not respondingCommon causesDead batteries, loose wiring, a blown low-voltage fuse at the furnace, a failed thermostatSystem affectedAll systems

Quick Checks Before You Call

These take a few minutes, need no tools, and sometimes solve the problem outright. Stop at anything that involves opening a panel or touching wiring.

  • Thermostat mode and setpoint: set to heat or cool, with the setpoint a few degrees past the room temperature, and the fan on “auto”.
  • The air filter: if it is grey and packed, replace it. A clogged filter alone can freeze a coil or overheat a furnace.
  • The breaker: look for a tripped breaker for the furnace or air handler and the outdoor unit. Reset it once; if it trips again, leave it off and call.
  • The vents: supply registers open and return grilles clear of furniture, rugs and curtains.
  • The outdoor unit: clear of leaves, weeds and anything stored against it, with at least a couple of feet of open space around the sides.
Finned coil above copper refrigerant piping inside an open stainless equipment cabinet Compressor with insulated copper refrigerant lines, seen through an open access panel

Repair Questions

What does a new noise from the system usually mean?

A squeal often points to a motor bearing or a belt on older equipment, a rattle to a loose panel or debris in the fan, and a steady hum from the outdoor unit that won’t start to a weak capacitor or a stuck motor. A bang or boom when a gas furnace lights is delayed ignition and should be looked at soon.

Why are some rooms comfortable and others not?

Uneven rooms usually come down to airflow. A duct that has come apart in the attic, a damper left half closed, a return that can’t pull enough air or a long duct run to the far end of the house all starve some rooms. Measuring the airflow at each register shows where it is being lost.

The system runs constantly. Is that a fault?

On the hottest afternoons a correctly sized air conditioner may run for long stretches. Running all day without reaching the setpoint is different: low refrigerant, a dirty coil, leaking ducts or a failing compressor can all cause it, and each wastes power until it is found.

When does a repair make sense, and when doesn’t it?

A repair makes sense when the rest of the system is in good shape: a capacitor, contactor, igniter or fan motor on a unit with years left in it. It makes less sense when the part is a major one, such as a compressor or a heat exchanger, on an older system that has needed several repairs. The Installations & Replacements page has a helper for weighing the two.

When It Can’t Wait

A gas smell, smoke, sparks, a burning smell from the furnace, water spreading across the floor, or no heat or cooling while someone vulnerable is at home are urgent. Safe steps for each, and when the first call goes to 911 or the gas utility, are on the Urgent Service page.

Tell us what the system is doing and when it started.